主要参数
压力范围* |
双向差分压力: |
-5 .. 5 mbar --> -1000 .. 1000 mbar |
差分压力/相对压力/表压: |
0 .. 5 mbar --> 0 .. 2000 mbar |
|
绝对压力: |
0 .. 1000 mbar --> 0 .. 2000 mbar |
|
大气压力: |
700 .. 1200 mbar |
|
总误差 (TEB) |
2.5 %FSO (max.) |
微压范围 (≤ 10 mbar) |
2.0 %FSO (max.) |
低压范围 (≤ 100 mbar) |
|
1.0 %FSO (max.) |
标准压力范围 (> 100 mbar) |
|
输出电压 |
4 .. 20 mA |
|
工作电压 |
8 .. 36 V (典型 24 V) |
FEATURES
Calibrated and temperature compensated pressure sensor with two-wire 4 .. 20 mA current loop output
Differential / gage, bidirectional differential, absolute and barometric versions
Wide variety of pressure ranges: 5 mbar up to 2 bar
Piezoresistive sensing element
High precision digital signal conditioning
High accuracy at room temperature
Low overall error within a temperature range of -25 .. +85°C
Supply voltage range: 8 .. 36 V
Current limitation
Protected against reverse polarity
Compact and robust package
Dust- and water-tight (IP67)
M5 circular sensor connector
Ready to use, simple and quick installation
RoHS and REACH compliant
GENERAL DEscriptION
AMS 4712 is a series of miniaturized pressure transmitters suitable for industrial applications and high precision measurements. All AMS 4712 can be powered within a supply voltage range of VS = 8 .. 36 V and provide an industrial two-wire 4 .. 20 mA current loop output. They are calibrated and temperature compensated in a wide temperature range of -25 .. +85°C.
AMS 4712 comes in a robust plastic package and is ready to use. Pressure is applied either via two barbed side ports for differential (relative) or bidirectional differential pressure transmitter types or via a single port for absolute or barometric types. The two-wire current loop output is established using an M5 circular sensor connector. AMS 4712’s package is dust- and water-tight conforming to IP67.
The pressure transmitters in the AMS 4712 series are available for various applications and pressure ranges: Differential (relative) devices in pressure ranges from 0 .. 5 mbar up to 0 .. 2 bar, absolute pressure variants for 0 .. 1 bar and 0 .. 2 bar as well as a barometric type for 0.7 .. 1.2 bar. Bidirectional differential devices are available from -5 .. +5 mbar up to -1 .. +1 bar for measurement of positive and negative pressure differences. Other pressure ranges are available on request.
TYPICAL APPLICATIONS
Static pressure sensing
Dynamic pressure sensing
Barometric pressure sensing
Vacuum measurement
Level measurement
Gas flow measurement
Heating, Ventilation and Air Conditioning (HVAC)